Make some analysis on some common problems (not including the problems caused by the low quality of the filling and sealing machine itself). First of all, before analyzing the specific problems that arise, Automatic Filling Sealing Machine  must be tested as follows:

1. Detect whether the actual running speed of the filling and sealing machine is the same as the initial debugging speed of this specification:. Detect if the LEISTER heater is in the ON position:

2. Check whether the compressed air supply pressure of the equipment meets the pressure requirements when the equipment is working normally:

3. Check whether the cooling water circulates smoothly, and whether the temperature of the cooling water is within the range required by the equipment;

4. Check whether there is ointment dripping in the filling and sealing machine, especially to ensure that the ointment does not stick to the upper part of the inner and outer walls of the tube:

5. The inner surface of the hose should not be in contact with anything to avoid contamination of the inner and outer walls of the hose:. Checking the air intake of the LEISTER heater

6. Check whether the temperature probe inside the heater is in the correct position. Check whether the heating head exhaust device is working normally

common specific problems of Automatic Filling Sealing Machine

Phenomenon 1: When Phenomenon 1 on the left appears, it is usually caused by excessive temperature. At this time, it should be checked whether the actual temperature is the temperature required for the normal operation of the hose of this specification. The actual temperature on the temperature display should be relatively stable with the set temperature (the normal deviation range is between 1°C and 3°C).

Phenomenon 2: There are ears on one side as shown in the figure below: first check whether the heating head is placed correctly

Place it in the heating head nest; then check the verticality of the heating head and the hose below. one side with ears

Another possible reason is that there is a deviation in the parallelism of the two tail clips. The deviation of the parallelism of the tail plate can be

Detection via a spacer between 0.2 and 0.3 mm

Phenomenon 3: The end seal starts to crack from the middle of the hose. This phenomenon means that the size of the heating head is not enough. Please replace it with a larger heating head. The standard for judging the size of the heating head is to insert the heating head into the hose, and then pull it out, and feel a slight suction when pulling it out.

Phenomenon 4: "eye bags" appear under the explosion-proof line of the tail seal: the appearance of this situation is that the height of the air outlet of the heating head is wrong, and it can be adjusted in the following way.

Phenomenon 5: The middle of the end of the hose is cut and the tail is sunken: This kind of problem is usually caused by the wrong size of the tube cup, and the hose is stuck too tightly in the tube cup. Criteria for judging the size of the tube cup: the hose should be fully clamped in the tube cup, but when the tail is clamped, the tube cup should not affect the natural change of the tube shape.